+27 64 987 3021 [email protected] Mon-Fri 8:00-17:30 (SAST)
Analyze Performance With Bit Error Rate Analysis App

Analyze Performance With Bit Error Rate Analysis App

Browse technical resources about ADSS/OPGW cables, 5G fronthaul, data center interconnect, and fiber optic testing.

  • BERT Error Rate Tester Calibration in Mali

    BERT Error Rate Tester Calibration in Mali

    BERT or bit error rate test is a testing method for that uses predetermined stress patterns consisting of a sequence of logical ones and zeros generated by a test pattern generator. A BERT typically consists of a test pattern generator and a receiver that can be set to the same pattern. They can be used in pairs, with one at either end of a transmission link, or singularly at one end with a at the remote end. BERTs are typically stand-alone specialised instruments, but can be.


  • QSFP optical module transmission rate

    QSFP optical module transmission rate

    QSFP data rate ranges from 40G to 800G depending on the module generation. In simple terms, QSFP is not a single speed standard—it is a scalable transceiver form factor used in data centers and telecom networks. For network engineers and procurement managers, the challenge isn't just. The original QSFP+ module supports 4 lanes of 10 Gbps transmission for a total aggregate bandwidth of 40 Gbps. QSFP28 increases the per-lane data rate to 25. Quad Small Form-Factor Pluggable Double-Density (QSFP-DD) offers twice as many high-speed electrical interfaces as QSFP28 while maintaining the same port density.


  • How to analyze relay protection

    How to analyze relay protection

    This guide explores the different types of protection relays and their testing procedures, with a focus on tools like secondary injection test sets and three-phase relay test sets. To properly test relays, understanding their classification by design and application is essential. To ensure that protective relays, circuit breakers, and other protection devices correctly and selectively isolate faults, minimizing damage to equipment and interruptions to customers while maintaining system stability. One-line diagrams and detailed network data (lines, transformers, buses). How much of the testing that we perform is a carryover from the electro-mechanical relay days? Are there any tests hat we need to add to accommodate new technology? What changes are needed in the way tests are performed to accommodat protective. Relion protection and control relays for several application reduce complexity.

    [PDF Version]
  • Loop error occurred at the aggregation switch

    Loop error occurred at the aggregation switch

    This guide will help you detect and fix network loops using Spanning Tree Protocol (STP), switch configuration adjustments, and loop prevention techniques. What Causes a Network Loop? A network loop can occur due to: ✅ Redundant Cable Connections – Multiple. STP provides a loop-free network at the Layer 2 level. Layer 2 LAN ports send and receive STP frames at regular intervals. If left unresolved, network loops can disrupt communication, slow down network performance, and even crash switches or. FS#show interface status //Check whether the port status of the aggregation member port is up. If the member port is down, check the physical port connection. If conditions permit, replace other member ports, confirm whether the aggregation member port can be up, and. I am experiencing a persistent adoption loop issue with a downstream switch and its connected APs whenever I upgrade the firmware on my main aggregation switch. Network Topology: - Gateway/Router: ER8411 - Controller Version: 6. When both legs of the LAG are.

    [PDF Version]
  • Analysis of Relay Protection Circuit Numbering

    Analysis of Relay Protection Circuit Numbering

    This handbook covers the code of practice in protection circuitry including standard lead and device numbers, mode of connections at terminal strips, colour codes in multicore cables, dos and donts in execution. In electrical power systems, clear communication is critical for safety and reliability. ANSI IEEE Standard Device Numbers are below: (the more commonly used ones are in bold) 86T is a Lockout Relay for a. These numbers are based on a system that is adopted by a standard for automatic switchgear by Institute of Electrical and Electronics Engineers (IEEE), and incorporated in American Standard C37. This system is used with diagrams that are found in instruction books and in specifications. The. The requirements for the different types of HV and LV circuits in a typical oil industry power system are summarised below. It includes 99 device functions numbered 1 through 99 with descriptions such as master element, time-delay starting or closing relay, AC time overcurrent relay, AC circuit breaker, exciter or DC generator.

    [PDF Version]

Need Product Pricing?

Contact us for competitive quotes on any of our fiber optic products

Get a Quote