+27 64 987 3021 [email protected] Mon-Fri 8:00-17:30 (SAST)
Edge Computing Architecture And Use Cases

Edge Computing Architecture And Use Cases

Browse technical resources about ADSS/OPGW cables, 5G fronthaul, data center interconnect, and fiber optic testing.

  • Energy-saving cost of MTP connectors for edge computing

    Energy-saving cost of MTP connectors for edge computing

    Edge computing is an emerging paradigm for the increasing computing and networking demands from end devices to smart things. Edge computing allows the computation to be offloaded from the cloud d.


  • How to use an OTDR fiber optic tester to find network cables

    How to use an OTDR fiber optic tester to find network cables

    To perform an OTDR test correctly, you must: 1. Set core parameters (Wavelength, Distance, Pulse Width); 4. Run the test (Real-time or Average); 5. An Optical Time Domain Reflectometer (OTDR) is the most powerful tool for characterizing fiber optic networks. It works like "radar for fiber optics," sending light pulses down the fiber and analyzing the reflected light to measure loss, locate faults, and verify installations. We'll give you the basic information you need and provide some printable references. This guide dives deep into OTDR technology, its applications, and how it integrates with modern components like optical transceivers.


  • Use of residual current circuit breaker in distribution box

    Use of residual current circuit breaker in distribution box

    Regulations differ widely from country to country. A single RCD installed for an entire electrical installation provides protection against shock hazards to all circuits, however, any fault may cut all power to the premises. A solution is to create groups of circuits, each with an RCD, or to use an RCBO for each individual circuit. In Australia, residual current devices have been mandatory on power circuits since 1.


  • How to use a splitter with a single fiber optic cable

    How to use a splitter with a single fiber optic cable

    A PLC Splitter takes one optical signal and splits it into many outputs. Lower ratios work for fewer users. Unlike active devices (which require power), splitters operate without electricity, relying solely on the physics of. Optical splitters offer a cost-effective and dependable solution across various fiber optic applications. This lets you connect more users to one network terminal.


  • Will ASIC chips use optical modules

    Will ASIC chips use optical modules

    Co-packaged optics (CPO) puts optical components right alongside—or even on top of—the data center switch ASIC. That's a shift from traditional pluggable optical modules. From Jensen Huang showcasing CPO switches at GTC 2025 to a wide range of vendors demonstrating optical engines integrated inside ASIC packages at OFC 2025, CPOs are everywhere. Right now, switches connect to network interface cards (NICs) using optical transceivers and digital signal processors (DSPs) to. Traditional electrical interconnects and pluggable optical module technologies are approaching their performance limits when dealing with network speed demands of 800G, 1. CPO offers a solution by reducing signal loss, improving power efficiency, and enabling.


Fiber Optic & Power-Grid Insights

Need Product Pricing?

Contact us for competitive quotes on any of our fiber optic products

Get a Quote