+27 64 987 3021 [email protected] Mon-Fri 8:00-17:30 (SAST)
Net Technology  Computer, Networking Amp Cctv

Net Technology Computer, Networking Amp Cctv

Browse technical resources about ADSS/OPGW cables, 5G fronthaul, data center interconnect, and fiber optic testing.

  • DWDM dense wavelength division multiplexing technology

    DWDM dense wavelength division multiplexing technology

    Dense wavelength-division multiplexing (DWDM) refers originally to optical signals multiplexed within the 1550 nm band so as to leverage the capabilities (and cost) of EDFAs, which are effective for wavelengths between approximately 1525–1565 nm (), or 1570–1610 nm (). EDFAs were originally developed to replace optical-electrical-optical (OEO), which they have made pra.


  • Hot aisle in industrial computer room

    Hot aisle in industrial computer room

    The hot aisle /cold aisle data center layout was originated by IBM in 1992 and it is one of the oldest ways to save energy in the data center. 1 Hot aisle/cold aisle layout involves lining up server racks in alternating rows with cold air intakes – the fronts of servers – facing each other (the. Traditional open aisle data centres use perimeter PAC (precision air conditioning) or CRAC (computer room air conditioning) units to channel cold air up through a raised floor void via grilles positioned in front of the IT cabinets. When implemented. Assuming a computer room is configured in such a way that either is an option, hot aisle containment may be seen as the better option because it has some thermal efficiency and ride-through advantages. However, because every computer room is unique, there is no one definitive solution. To maintain thermal performance, equipment accessibility, and safety, it's essential to follow key spatial guidelines. Maximum Aisle Length: When equipment cabinets form a continuous row.

    [PDF Version]
  • Computer Network System Cabinet Dimensions

    Computer Network System Cabinet Dimensions

    Get a comprehensive guide on server rack cabinet sizes and dimensions. Understand the depth, width, and height requirements to fit your IT needs. Optimum positioning for PDUs – suitable for plugs of up to 32A. Ro it back door with Fix Easy locking. (Place serial numbers, barcodes or QR codes here to en ode and personalise your. This report provides a comprehensive analysis of network cabinet sizes, focusing on industry standards, emerging trends, and specific product segments including enterprise-grade racks and compact wall-mount solutions. This research covers the global server and network cabinet market, focusing on. The right cabinet size depends on three things: how much equipment you have now, how much space you have available, and how much room you need for future growth. The letter “U” stands for something called a rack unit. Our racks come with various options, depending on the product, including. 1. Split, perforated sheet steel rear door, multi-piece roof plate for side cable entry on both sides, open base frame, without side panels.

    [PDF Version]
  • What level of optical splitter is installed in the computer room

    What level of optical splitter is installed in the computer room

    In two-stage splitting applications, the first-stage optical splitter is often installed in an optical distribution box or a fiber-splitting box, while the second-stage optical splitter is often installed in a local residence or community closer to the end-user. Selecting the right splitter is crucial for building a reliable fiber optic network. PLC splitters are based on planar lightwave circuit technology, ensuring uniform signal distribution and supporting high split ratios up to 1×64 or even higher. They are ideal for large-scale deployments such as. The first level of splitting (1:4 or 1:8) is installed in a closure, not far from the central office.


  • Dehumidification of the hot aisle in the computer room

    Dehumidification of the hot aisle in the computer room

    Install the dehumidifier intake on the return air path (hot aisle side) where moisture content is highest. Position condensate drainage with redundant paths. As computer room air conditioning units (CRACs) were controlled to relatively low supply air temperatures, it was not uncommon for a CRAC unit to dehumidify the room air while at the same time a different CRAC unit could be in humidification mode. Such a humidity-control strategy is like. This article explains practical approaches to air conditioning for computer rooms, focusing on maintaining stable temperatures and humidity, selecting suitable systems, and implementing maintenance practices that minimize downtime and energy use. Operating above 60% RH accelerates corrosion on copper and silver contacts inside servers. Data centers generate heat every second of every day. Servers, storage equipment, network switches, UPS systems, power distribution equipment, and high-density computing racks all produce heat that must be removed continuously.

    [PDF Version]
  • Grounding of the outer sheath of optical cable in the computer room

    Grounding of the outer sheath of optical cable in the computer room

    Follow these steps at each cable entry point and termination location to achieve a compliant, safe ground bond: Identify metallic components. Strip back approximately 6–8 inches of the outer jacket using a cable slitter or ringing tool. Visually identify armor, strength members, or. Fiber optic cable transmits data as light through glass or plastic strands, which means the fiber core itself carries no electrical current and requires no grounding. The critical distinction lies in. Grounding of cable shield or outer sheath at both ends can results in circulating currents that may require cable derating, depending on the cable length and construction. A table is provided by ANSI/IEEE 525 recommending the maximum lengths of single point shield grounding. Operational grounding rules, especially for medium and high-voltage grids, may vary according to each country's regulations. Refer to Table 1 for kit part numbers. Contact your customer service representative to. Armored fiber-optic cable bonding and grounding are simple phases in the installation process but are sometimes misunderstood or omitted. It offers ruggedness and superior crush resistance.

    [PDF Version]
  • Fiber optic cable protection pipe in the computer room

    Fiber optic cable protection pipe in the computer room

    PVC Riser Pipe is a lightweight, flame-retardant plastic conduit specifically designed to encompass and shield fiber optic cables. It shields cables from environmental hazards such as wind, rain, UV rays, and physical damage caused by accidental snags or deliberate vandalism. Whether for underground or overground installations, you have a wide choice of cable protection solutions to ensure your power and cable lines are fully protected during repair, retrofitting or constrution work. Either rigid or flexible, made of PE, PP or PVC, sand-proof, waterproof or fireproof. Fiber optic cable carries enormous amounts of data, but the glass or plastic fiber at its core is unforgiving of mechanical stress, moisture infiltration, and improper installation practices. Unlike copper cable, fiber does not tolerate being kinked, crushed, or over-tensioned during a pull. They can be used in all areas of general construction and civil engineering, in road construction and also in the construction of tunnels and tracks.

    [PDF Version]
  • Cost of optical module networking

    Cost of optical module networking

    OEM list prices can reach several thousand dollars per module. Compatible third-party alternatives can start as low as $35 for common short-reach models. In many cases, the biggest differences are not optical performance, but branding, EEPROM coding, warranty process, and vendor support structure. In today's rapidly evolving network environments, reducing operational costs is a top priority for data centers, telecom operators, and system integrators. As network bandwidth demands continue to grow—driven by cloud computing, AI workloads, and high-density. Understanding Optical transceiver Pricing helps procurement, network planning, and total cost-of-ownership decisions. This article compares typical cost ranges across speeds and transceiver types, explains why prices vary, and gives practical guidance for choosing the right optics for a given. Data centers accounted for 45% of global optical module revenue in 2022, driven by rising cloud computing and AI workloads. 8 billion in 2025 and is projected to reach $26. 6% during the forecast period from 2026 to 2034. This robust growth trajectory is underpinned by an unprecedented.

    [PDF Version]
  • How high is the power distribution box in the computer room from the ground

    How high is the power distribution box in the computer room from the ground

    The proper installation of a distribution box involves placing it at the right height to ensure safety and convenience. Wireway Depth: The maximum permitted distance for the through. The electrical panel, often referred to as the breaker box or service panel, serves as the main distribution hub for all electrical power within a home or building. This table outlines the specific distances for Condition 1, 2, and 3 scenarios.


  • Advantages and disadvantages of small busbars in computer rooms

    Advantages and disadvantages of small busbars in computer rooms

    • Busbars improve protection, maintenance, and supply continuity. An electrical busbar functions as a metallic conductor, playing a pivotal role as a central link for multiple electrical connections. These important components are known as Busbars. Instead of using many individual cables. Square shape busbars are rarely used because of worse ventilation, and assembly is more difficult. High cost is the most significant disadvantage. It compares copper and aluminium busbars, noting copper's superior electrical performance and aluminium's lighter weight and lower cost.


  • Function of Computer Optical Modulators

    Function of Computer Optical Modulators

    An optical modulator is a device that tweaks the properties of an optical beam—like its intensity, phase, or polarization—using an electrical signal. These nifty gadgets are the backbone of high-speed data transmission, laser technology, and even some scientific measurements. The beam may be carried over free space, or propagated through an optical waveguide (optical fibre). Each type works best for certain speeds and distances. They also help keep errors low. Performance metrics like. Optical modulators are a foundational building block in fiber-optic communication and laser systems because they provide a controlled, repeatable way to translate electrical information into changes in a light wave.


  • Wavelength Division Multiplexing Technology Number

    Wavelength Division Multiplexing Technology Number

    WDM systems are divided into three different wavelength patterns: normal (WDM), coarse (CWDM) and dense (DWDM). Normal WDM (sometimes called BWDM) uses the two normal wavelengths 1310 and 1550 nm on one fiber. Coarse WDM provides up to 16 channels across multiple transmission windows of silica fibers. OverviewIn, wavelength-division multiplexing (WDM) is a technology which a number of signals onto a single by using different (i.e., colors) of. A WDM system uses a at the to join the several signals together and a at the to split them apart. With the right type of fiber, it is possible to have a device that does both s.


  • PON technology optical cable

    PON technology optical cable

    A passive optical network (PON) uses fiber-optic technology to deliver data from a single source to multiple endpoints. "Passive" refers to the use of optical fiber cables connected to an unpowered splitter, which in turn transmits data from a service. 3 Passive Optical Network (PON) technologies CHARACTERISTICS OF PON Fiber broadband in a nutshell In a PON access network there are two end-points with active (powered) electronic transmission equipment, connected by passive (non-powered) equipment known as outside fiber plant. Instead of running a separate fiber strand to every home or office, a PON shares a single fiber using optical. Passive Optical Network (PON) stands as a foundational technology in the evolution of modern telecommunications, serving as the cornerstone for high-speed fiber-optic networks.

    [PDF Version]
  • India Customized Silicon Photonics Technology 10G

    India Customized Silicon Photonics Technology 10G

    On Friday, at IIT Madras, the Ministry of Electronics and IT (MeitY) formally launched two indigenously developed Silicon Photonics technology solutions, tools that are designed to help India design and eventually manufacture photonic chips. The Technology Transfer Office (TTO), IIT Madras, signed the ₹1 crore. MeitY Secretary Mr. Krishnan, IAS, launches Silicon Photonics products indigenously developed at CoE-CPPICS IIT Madras Shri S. Shanti Bhattacharya, HoD, DoEE, IIT.


Need Product Pricing?

Contact us for competitive quotes on any of our fiber optic products

Get a Quote