+27 64 987 3021 [email protected] Mon-Fri 8:00-17:30 (SAST)
Time Now In Aest Australian Eastern Standard Time

Time Now In Aest Australian Eastern Standard Time

Browse technical resources about ADSS/OPGW cables, 5G fronthaul, data center interconnect, and fiber optic testing.

  • Emergency power distribution box power supply time

    Emergency power distribution box power supply time

    The National Electrical Code requires emergency systems to restore power within 10 seconds and legally required standby systems within 60 seconds. Noncompliance can trigger inspection failures, voided insurance coverage, or loss of a building's certificate of occupancy. Emergency and standby power systems are designed to provide an alternate source of power if the normal source of power, typically the electric utility service, should fail. It's measured in hours, so a Class 0.


  • Overcurrent Time Limit of Relay Protection

    Overcurrent Time Limit of Relay Protection

    In protective relay-based systems, the time overcurrent protection function is designated by the ANSI/IEEE number code 51. Time overcurrent protection allows for significant overcurrent magnitudes, so.


  • Optical Time Domain Reflectometer ckot

    Optical Time Domain Reflectometer ckot

    An Optical Time-Domain Reflectometer measures signal loss in an optical fiber by launching a series of optical pulses into the fiber and analyzing the back-scattered light. The working principle of an OTDR is based on Rayleigh scattering and Fresnel reflections. Essential for both installation and maintenance, OTDRs ensure network reliability with accurate fault location. Ensure the integrity of your fiber optic network with an Optical Time Domain Reflectometer (OTDR). OTDR testing analyzes fiber optic cable performance from end to end by testing components along the cable, including connection points, bends, and splices. in cable TV, LAN, metropolitan networks or long-haul. e an essential tool for: characterisation, certification, maintenance and monitoring optical networks.

    [PDF Version]
  • FTB-150 Optical Time Domain Reflectometer Usage

    FTB-150 Optical Time Domain Reflectometer Usage

    The Exfo FTB-150 is a compact optical time-domain reflectometer (OTDR) designed for network testing. It offers high-performance testing capabilities in a portable form factor. This small and lightweight OTDR is a dedicated platform with all EXFO OTDR configurations factory pre-installed. You can choose the model that best suits your testing requirements and working conditions. No part of this publication may be reproduced, stored in a retrieval system or transmitted in any form, be it electronically, mechanically, or by any other means such as photocopying, recording or otherwise, without the prior writt eved to be accurate and reliable. It can be used to locate faults in fibers, measure the length of fibers, and characterize the optical properties of fibers.

    [PDF Version]
  • What is the power of an optical time domain reflectometer

    What is the power of an optical time domain reflectometer

    The instrument emits short laser pulses, e. some tens of nanoseconds and a peak power of a few hundred milliwatts, as can be obtained with a single-mode laser diode. An optical time-domain reflectometer (OTDR) is an optoelectronic instrument used to characterize an optical fiber. With the rapid growth of telecommunications and data transmission, ensuring the integrity and performance of fibre optic connections has become paramount.


  • Mesh cable tray time

    Mesh cable tray time

    Thanks to the connection system developed by OBO, the mesh cable tray can be mounted in a matter of seconds – without any connectors or tools. Just connect the two parts and you're done. At temperatures below - 20 °C, the material will be any other purpose than. Traditional trays expect certainty. The GR-Magic®, the Magic® G mesh cable tray, and the heavy-duty SGR mesh cable tray with their various shapes, side heights, surfaces and. maintain spacing or to keep cables in place when the tray is ect the minimum bend ra-dius for cables as they exit the bottom of the cable tray. A rung spacing of 6 to 9 inches (150 to 230 mm) is preferable when the cable tray cont d for instrumentation and control applications that require. Mesh trays reduce installation time while supporting compliance.

    [PDF Version]
  • Same relay protection time limit

    Same relay protection time limit

    The various protective functions available on a given relay are denoted by standard. For example, a relay including function 51 would be a timed overcurrent protective relay. An overcurrent relay is a type of protective relay which operates when the load current exceeds a pickup value. It is of two types: instantaneous over current (IOC) relay and definite time overcurrent (DTOC) relay.


  • Distribution box trips all the time

    Distribution box trips all the time

    Common causes include overloaded circuits, short circuits, and ground faults. High-powered appliances can easily trip breakers if too many are used at once. Frequent tripping of your distribution box is a critical alarm, not just an annoyance. For facility managers, electricians, and project owners operating overseas—from industrial plants in the Middle East to solar farms in Southeast Asia—these unexpected shutdowns mean costly downtime, safety risks. A circuit breaker keeps tripping because it is detecting an unsafe electrical condition, most commonly a circuit overload, short circuit, ground fault, or wiring problem. But what's causing it? And more importantly, does it need an expensive fix, or is this something simple? The good news: Most circuit breaker trips have straightforward. If your circuit breaker keeps tripping, there is probably an issue that you need to resolve. It. It means your electrical system is repeatedly operating outside safe limits, and the breaker is doing exactly what it's designed to do: stop damage before it gets worse. In commercial buildings, industrial facilities, and OEM-installed systems, we see this mistake all the time.

    [PDF Version]
  • Standard for cable tray tensile length

    Standard for cable tray tensile length

    The standard NEMA lengths for cable tray are 12, 20, 24 and 30-feet, although some manufacturers like Eaton offer cable tray in lengths up to 40 feet. Selecting a cable tray length is based on several criteria, including: The required load that the cable tray must. us-trations without notice. All illustrations, descriptions and technical information included in this document are provided as indications and can cable trays are equivalent. The mechanical and electrical characteristics, tests, certifications, overall quality management, recommendations mentioned. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or IEC's member National Committee in the country of the requester. Each type serves a different purpose in electrical installations.

    [PDF Version]

Fiber Optic & Power-Grid Insights

Need Product Pricing?

Contact us for competitive quotes on any of our fiber optic products

Get a Quote